V2.xx is valid for LFH3200, LFH3210, LFH3220, LFH3300, LFH3310, LFH3500, LFH3510, LFH3520, LFH3600, LFH3610

 

V2.56 technical release 2017-07-27

Now left and right mouse button work also in Keyboard mode. String descriptor indexes greater than the allowed ones are filtered now.

 

V2.55 technical release 2016-03-14

Decreased the two-buttons switch time between Keyboard-Command and HID-Command mode to 3 secs. Modified I2C-bus protocol handling to avoid corruption of LFH number. Modified transfer of new firmware version into EEPROM to avoid corruption of internal flash memory and render the device nonfunctional.

 

V2.54 technical release 2015-10-23

Modfified the audio streaming in record mode for 16KHz sampling rate to solve audio problems with the new Apple OSX ‘El Capitan’(10.11).

 

V2.53 technical release 2015-06-08

The motion detection is also effective in Keyboard mode now. Requesting the history of past button press events is possible now. The default setting of ‘Disable PC-screen-saver’ can be turned off/on now by simultaneously pressing the left mouse button and trackball button for five seconds.

 

V2.51 technical release 2014-12-17

The polling rate for the HID-interface, which is reporting the keypress events, has been increased from 10 to 16 frames. This is just an attempt to help a customer who is complaining about intermittent SpeechMagic problems. The source-code has not been changed! Only the USB-descriptor for the HID-interface reports a polling rate of 16 frames to the USB-host. The USB-host is not obliged to poll at exactly 16ms, but must not poll any faster than the reported value of 16ms.

 

V2.50 technical release 2014-11-03

Fixed a rare problem, where the accelerator sensor reported a picked-up event even when the device was sitting motionless on a table top.

The USB-interface is reinitialized every time an audio stream is started to avoid lost recordings.

Introduction of Keyboard-mode: when selected, the device sends keyboard shortcut events to the host instead of the propriatory HID commands when a button is pressed. Works only with SMP versions.

 

V2.19 technical release 2014-03-28

Fixed a problem, where moving the mouse trackball during OS booting causes the device to stop working after the boot process has finished.

 

V2.18 technical release 2014-02-14

Fixed a problem where communication problems within the device stopped the device to respond to pressed buttons or trackball movements.

Under some rare circumstances the USB driver on the host missed a button or slider event. Each button and slider event is now sent twice to avoid these situations.

The polling rate of the HID-interface, which handles Speechmike proprietary information, has been changed from 8msec intervals to 4msec intervals to avoid occasional connecting problems with hosts, where a Speechmike-aware application is already running.

The handling of audio settings has been changed in V2.15, which causes occasional delays when starting speech recognition with Dragon Dictate. V2.18 reverts now to the former method to avoid these delays.

Linux does not poll unused USB interfaces of a device (which is against specification). This can cause problems, when no Speechmike-aware application is running, and a button is pressed unintentionally. In that case the Speechmike will wait until a Speechmike-aware application is started, and will not react to trackball movements till then. This has been fixed.

A level limiter has been implemented in record mode to reduce signal overdrive.

 

V2.15 technical release 2013-07-01

Fixed a problem where communication problems within the device stopped the device to respond to pressed buttons or trackball movements.

 

V2.13 technical release 2013-04-04

Fixed a problem which caused corruption of the barcode-table in barcode scanner Speechmikes and also made the Speechmike becoming irresponsible to buttons, slider and mouse commands.

Decreased the communication speed of the keyboard interface on Speechmikes with barcode scanner to minimize the risk of losing part of the scanned character string  when the PC-CPU is extremely busy.

Fixed a problem which caused an asynchronicity between the position of the slider switch and the position recognized by the host SW.

The minimum volume position will mute the device also under Windows 7, like it did under Windows XP.

V2.10 technical release 2012-10-25

Sending of motion events is automatically disabled in FW when SMP is initialized by a PC-SW that does not support motion events.

Modified the USB communication protocol between PC and SMP to fix timing issues.

Fixed a problem where the internal trackball sensor stopped working when the trackball was moved vigorously during initialization of the Speechmike.

Fixed an issue with microphone sensitivity when the motion control configuration was changed during operation.

 

V2.08 technical release 2012-09-03

Older PC-software recognizes the SpeechMike Premium as a SpeechMike III for compatibility reasons. Because of that it was possible to downgrade a Premium device to an older 1.xx FW-version, rendering the device dead - this problem is fixed now.

Suppressed the first static motion sensor event to avoid interference with initialization routines from older PC-software after device is plugged in or reset after a firmware upgrade.

HID interfaces are configured only once now.

 

V2.05 technical release 2012-08-02

This version supports – beside the ‘classic’ line of SpeechMike III – also the new range of SpeechMike III Premium. This includes new features like position detection, scrolling up/down and additional buttons.

 

 

V1.xx is valid for LFH3200, LFH3210, LFH3220, LFH3300, LFH3310

 

V1.17 technical release 2012-05-23

Changed protocol for handling HID-commands to improve stability on fast PC platforms. Now host requests are acknowledged after the request has been processed by the device.

 

V1.15 technical release 2012-02-21

Introduction of a 'SMII-compatibility-mode'. Changing modes is done by pressing F1 + F3 buttons simultaneously for more than five seconds. The F2-Led will light for five seconds afterwards when switching to 'SMII-mode', and accordingly the F3-Led when going back to 'SMIII-mode. A short beep will finally acknowledge the operation. Firmware upgrade and assigning new functionalities to buttons is not possible when in SM2 mode.

Muting time for switch click suppression increased from 40ms to 60ms.

 

V1.14 technical release 2011-08-18

Users of the Dragon Systems Speech Recognition Engine reported delayed output of recognized text in connection with a SpeechMike III.

This issue could be fixed by modifying the switch click suppression.

 

V1.13 technical release 2011-07-14

Fixed a problem under Linux, where the slider versions of SMIII (LFH3210,LFH3220,LFH3310) were not recognized.

Added a third selectable audio sample rate of 16KHz to resolve streaming issues on the Apple platform with 22050Hz and 44100Hz sampling rate.

Changed timing to resolve issues on certain platforms with the Philips proprietary HID-interface (SpeechExec hanging at startup, unreliable operation during dictation).

 

V1.11 technical release 2011-05-25

Because of a changed timing of the HID-command interface, commands were lost under some special circumstances. Doubling the size of the HID-command queue buffer fixed the problem

 

V1.10 technical release 2011-05-24

Several issues have been fixed compared to the previous version:

Some customers reported long boot times with their Dell-PCs when a Speechmike III was connected – fixed

Sometimes recording sensitivity was still too low for the SpeechMagic wizard – upper limit has been increased for an additional +3dB

Device wizard hangs when started right after scanning a barcode – fixed

Some customers reported a startup problem of SpeechExec with an attached Speechmike III - fixed

 

V1.02 technical release 2010-11-10

Nuance reported a problem where the Audio Wizard of SpeechMagic was not able to adjust the recording sensitivity when the input speech was low.

An increase of +6dB of the upper limit of the adjustment range fixed the problem, while still working fine with Dragon.

 

V1.01 technical release 2010-07-20

Fixed problem where muting of button clicks interfered with muting of audio channel initiated by host, which caused problems with Dragon Speech Recognition.

Modified break-points of slider-switch-modes on slider models.

 

V1.00 technical release 2010-06-24

Initial version

 